E.coli cfu per 100mL
What's this?
0.0
Old Trace Park : Ross Barnett Reservoir
Ridgeland, Mississippi, United States
Observed by
Jennifer Sigrest
- Observed on: Sat, 27 Jul 2024 14:00:00 -0500
- Testers Jennifer Sigrest
-
Associated with:
Mississippi State University : Mississippi Water Stewards - Lat: 32.4243659
- Lng: -90.0802732
Observation report
See trends at this locationWater quality tests
Pending Quality Check from Water Rangers What's this?
Other coliform cfu per 100mL
What's this?
1,200.0
Total coliform cfu per 100mL
What's this?
1,200.0
Air temperature °C
What's this?
33.0
Incubation time (hours)
What's this?
24.0
Water temperature °C
What's this?
31.0
Incubation temperature °C
What's this?
36.0
Microplastics
Weather
Current weather What's this?
Weather in previous 24 hours What's this?
Latest photos
Notes
Delayed in sampling due to several rainy days. Several people observed enjoying the park today. It appears as though the entire upper part of the retaining wall that functioned as a kind of sidewalk across the shore of Old Trace Park is being replaced with loose rocks